Posted in

How can I tell if a lightning arrester has been damaged by a lightning strike?

Hey there, fellow folks in the electrical game! I’m Jake, part of the team that’s been supplying lightning arresters for over 12 years now—got scars from testing bad units out in the rain, and I’ve fielded way too many panicked calls from clients asking, “Did that lightning fry my arrester?” If you’ve ever had a storm roll through and wondered if your go-to protection took a hit, you’re in the right spot. No stuffy lab jargon here—just real, actionable stuff I’ve learned from being on job sites, troubleshooting, and working with technicians every single day. Lightning Arrester

Let’s start with the basics: a lightning arrester (we call ‘em LAs for short around here) is basically the bodyguard for your gear—transformers, panels, even that fancy new solar array you just installed. It siphons off the excess lightning current that’d otherwise turn your equipment into a paperweight. But when that bodyguard takes a direct hit, how do you tell it’s not just doing its job?

First off, don’t skip the walkaround. After a storm, the first thing I tell our clients is to do a visual check—no climbing poles if you don’t know what you’re doing, okay? Safety first, always. If you can get a clear look from the ground, here’s what to hunt for. Cracked ceramic? Yeah, that’s a red flag. Most LAs have that hard, heat-resistant ceramic housing—if there’s a spiderweb crack, a big chunk missing, or even a small gouge where lightning might have burned through, that’s a sign the strike punched through the outer layer. Wait, not just any crack—if it’s tiny from age, maybe that’s normal. But if it’s fresh, right after a storm? That’s damage.

Then there’s the color. Lightning superheats everything it touches. If your LA used to be that nice neutral gray (or whatever color the manufacturer makes), and now parts of it are black or even brownish-black, that’s thermal damage. Lightning heats up to 50,000 degrees F—way hotter than the surface of the sun. If it burned the coating or even the inner components, you’ll see that discoloration. Sometimes there’s a faint burnt smell too—stand downwind a bit, but don’t lean in. That’s not just the grass; that’s your arrester’s rubber or insulation burning.

Another visual tell: loose connections. Lightning’s current surge is intense—way more than normal power flow. It can rattle bolts, loosen lugs, even twist the mounting hardware holding your LA up. If the unit feels wobbly (again, from the ground—don’t tug on it if you’re not trained), or you see wires that look pulled tight or even frayed at the connection points, that’s a sign the strike put stress on it. We’ve had a client last month who thought their transformer was broken, only to find the LA’s top lug was loose from the surge. That’s a fixable thing, but if the connections are loose, the LA might not work next time.

Now, what if the visual check looks fine? Don’t breathe easy yet. A lot of LA damage isn’t visible—lightning can fry the internal metal-oxide varistors (MOVs, the main part that does the surge absorbing) and you can’t see those unless you take the unit apart, which we don’t recommend unless you’re a pro. That’s why the next step is a quick electrical test. You can do this with a basic insulation tester (a megger, if you want the real name) or a surge arrester tester—nothing too fancy, and a lot of small electrical contractors have these on their trucks.

Here’s the test: You disconnect the LA from the system (turn the power off, obviously—safety again) and test its insulation resistance. A good LA should have a super high resistance—like, 10,000 megaohms or more. If it’s below 1,000, that’s a bad sign. That means the MOVs inside have shorted out, or the insulation broke down. Now, another test is the leakage current test. Even when the LA’s off, a tiny amount of current should leak through—usually less than 1 milliamp. If it’s higher, that means the lightning surge damaged the internal components, and it’s not going to work the next time a storm hits.

Wait, I’ve seen people skip this test and just assume if the lights stayed on, the LA’s fine. That’s a mistake. Lightning can strike nearby, create a surge, and the LA might have absorbed that, but the surge still did damage. Last year, a guy told me his “surge protector for the whole house” (which was actually a LA) worked because his TV didn’t break—turns out the internal MOVs were already halfway gone, and the next big storm would’ve fried his HVAC. So testing non-visible damage is non-negotiable.

Also, let’s talk about age. A lightning arrester that’s 10 years old? It’s gonna wear out, even without a strike. They don’t last forever—heat, humidity, UV from the sun, all that stuff degrades them over time. If a storm rolls through and you notice your LA’s 12 years old, that’s a double whammy. The strike might’ve pushed it past its limit. Even if the tests come back “okay,” I’d lean toward replacing it just to be safe—your equipment’s worth more than a new LA.

What about if it’s a gas-filled arrester? Wait, those are less common now, mostly in older systems. If you have one, check for a pressure relief vent. A lot of gas-filled units have a little button or a disc that pops out if the internal pressure gets too high from a strike. If that vent’s popped, the gas leaked out, and the arrester’s useless. That’s a big one—we had a commercial client who didn’t notice their vent popped after a storm, and a week later another strike fried their entire backup generator. Cost ‘em way more than replacing the arrester would’ve.

Let me throw in a real story here, ‘cause that’s what we do. Back in 2021, a farm down in Ohio called us after a storm. They had three LAs on their grain silo transformers. The visual check looked fine—no cracks, no discoloration. So they ran the megger test. One of the three had an insulation resistance of 200 megaohms—way below the normal 10k. We sent our guy out to take a look, and when he opened the unit, the MOVs inside were all crumbly—lightning had fried them from the inside out. That farm avoided losing $50k worth of grain (they were harvesting that week) just ‘cause they tested. If they’d skipped, next time a strike hit, no LA meant no protection.

Another common mistake: people think if the LA is still “in one piece,” it’s good. Nope. I’ve seen LAs that looked totally intact on the outside, but inside, the varistors were shorted. The surge made the internal metal expand so fast, it cracked the MOVs without breaking the ceramic. So visual checks are step one, not step all.

What should you do if you think your LA is damaged? First, get a pro. Don’t mess with high-voltage stuff if you’re not trained—seriously, that’s how people get hurt. A licensed electrician or a LA technician can do the tests, tell you if it’s repairable (most of the time, they’re not—you replace ‘em) or if you need a new one.

Now, as a supplier, I’ll be honest with you: we’ve seen our fair share of LAs that looked like they took a direct hit, tested fine, and kept working. But we’ve also seen ones that looked brand new, tested bad, and failed 3 months later. The key here is consistency—don’t just check after a big storm. Do a quick visual once a year, especially if you’re in a lightning-prone area (Florida, Texas, the Plains—we see a lot of clients there). And if you have a storm with really heavy lightning, give your LAs a once-over.

Wait, one more thing: what if the system has a surge protective device (SPD) instead of a LA? They’re different—SPDs are for inside your building, LAs are for outside on the power lines. But the same logic applies: if there’s a storm surge, check the SPD for a blown fuse or a little indicator window that turns red. If that’s the case, replace it too. But this blog’s about LAs, so I’ll stick to that.

Let’s wrap this up. To recap, here’s your quick checklist:

  1. Visual check after storms: Look for cracked ceramic, burnt discoloration, loose connections, popped pressure vents (for gas units).
  2. Electrical test: Megger insulation resistance (aim for 10k+ megaohms), check leakage current (under 1 milliamp).
  3. Factor in age: If it’s over 10 years old, even if it looks fine, think about replacement—wear and tear makes damage more likely.

I know this stuff can feel overwhelming, especially if you’re new to the electrical side. That’s why we’re here. Whether you need a replacement LA, a quick answer to a question, or help scheduling a tech to come test your units, don’t hesitate to reach out. We’ve got years of experience, and we’re not just a supplier—we’re folks who work on the same job sites you do, so we get how important this is.

Now, before I go, let’s list the sources I relied on for all this stuff—nothing fancy, just the real industry stuff we use every day.

References:

  • IEEE Standard for Surge Arresters for AC Power Circuits (IEEE C62.11)
  • National Electrical Code (NEC) Article 280, Surge Arresters
  • Lightning Protection Institute (LPI) Technical Bulletin on Arrester Damage Assessment
  • “Lightning Surge Effects on Distribution Equipment” by the Electrical Power Research Institute (EPRI)
  • Our own 12 years of on-site testing and client troubleshooting data.

Meteorological Sounding System That’s it, folks. Stay safe out there, and when in doubt, check your LAs. We’re here if you need us for all your lightning protection needs.