{"id":643,"date":"2026-11-09T12:35:56","date_gmt":"2026-11-09T04:35:56","guid":{"rendered":"http:\/\/www.novdim.com\/blog\/?p=643"},"modified":"2026-11-09T12:35:56","modified_gmt":"2026-11-09T04:35:56","slug":"how-can-i-tell-if-a-lightning-arrester-has-been-damaged-by-a-lightning-strike-495a-c23e85","status":"publish","type":"post","link":"http:\/\/www.novdim.com\/blog\/2026\/11\/09\/how-can-i-tell-if-a-lightning-arrester-has-been-damaged-by-a-lightning-strike-495a-c23e85\/","title":{"rendered":"How can I tell if a lightning arrester has been damaged by a lightning strike?"},"content":{"rendered":"<p>Hey there, fellow folks in the electrical game! I\u2019m Jake, part of the team that\u2019s been supplying lightning arresters for over 12 years now\u2014got scars from testing bad units out in the rain, and I\u2019ve fielded way too many panicked calls from clients asking, \u201cDid that lightning fry my arrester?\u201d If you\u2019ve ever had a storm roll through and wondered if your go-to protection took a hit, you\u2019re in the right spot. No stuffy lab jargon here\u2014just real, actionable stuff I\u2019ve learned from being on job sites, troubleshooting, and working with technicians every single day. <a href=\"https:\/\/www.blooming-tech.net\/meteorological-instruments\/lightning-arrester\/\">Lightning Arrester<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.blooming-tech.net\/uploads\/47475\/page\/small\/low-altitude-wind-measurement-radar8add3.jpg\"><\/p>\n<p>Let\u2019s start with the basics: a lightning arrester (we call \u2018em LAs for short around here) is basically the bodyguard for your gear\u2014transformers, panels, even that fancy new solar array you just installed. It siphons off the excess lightning current that\u2019d otherwise turn your equipment into a paperweight. But when that bodyguard takes a direct hit, how do you tell it\u2019s not just doing its job?<\/p>\n<p>First off, don\u2019t skip the walkaround. After a storm, the first thing I tell our clients is to do a visual check\u2014no climbing poles if you don\u2019t know what you\u2019re doing, okay? Safety first, always. If you can get a clear look from the ground, here\u2019s what to hunt for. Cracked ceramic? Yeah, that\u2019s a red flag. Most LAs have that hard, heat-resistant ceramic housing\u2014if there\u2019s a spiderweb crack, a big chunk missing, or even a small gouge where lightning might have burned through, that\u2019s a sign the strike punched through the outer layer. Wait, not just any crack\u2014if it\u2019s tiny from age, maybe that\u2019s normal. But if it\u2019s fresh, right after a storm? That\u2019s damage.<\/p>\n<p>Then there\u2019s the color. Lightning superheats everything it touches. If your LA used to be that nice neutral gray (or whatever color the manufacturer makes), and now parts of it are black or even brownish-black, that\u2019s thermal damage. Lightning heats up to 50,000 degrees F\u2014way hotter than the surface of the sun. If it burned the coating or even the inner components, you\u2019ll see that discoloration. Sometimes there\u2019s a faint burnt smell too\u2014stand downwind a bit, but don\u2019t lean in. That\u2019s not just the grass; that\u2019s your arrester\u2019s rubber or insulation burning.<\/p>\n<p>Another visual tell: loose connections. Lightning\u2019s current surge is intense\u2014way more than normal power flow. It can rattle bolts, loosen lugs, even twist the mounting hardware holding your LA up. If the unit feels wobbly (again, from the ground\u2014don\u2019t tug on it if you\u2019re not trained), or you see wires that look pulled tight or even frayed at the connection points, that\u2019s a sign the strike put stress on it. We\u2019ve had a client last month who thought their transformer was broken, only to find the LA\u2019s top lug was loose from the surge. That\u2019s a fixable thing, but if the connections are loose, the LA might not work next time.<\/p>\n<p>Now, what if the visual check looks fine? Don\u2019t breathe easy yet. A lot of LA damage isn\u2019t visible\u2014lightning can fry the internal metal-oxide varistors (MOVs, the main part that does the surge absorbing) and you can\u2019t see those unless you take the unit apart, which we don\u2019t recommend unless you\u2019re a pro. That\u2019s why the next step is a quick electrical test. You can do this with a basic insulation tester (a megger, if you want the real name) or a surge arrester tester\u2014nothing too fancy, and a lot of small electrical contractors have these on their trucks.<\/p>\n<p>Here\u2019s the test: You disconnect the LA from the system (turn the power off, obviously\u2014safety again) and test its insulation resistance. A good LA should have a super high resistance\u2014like, 10,000 megaohms or more. If it\u2019s below 1,000, that\u2019s a bad sign. That means the MOVs inside have shorted out, or the insulation broke down. Now, another test is the leakage current test. Even when the LA\u2019s off, a tiny amount of current should leak through\u2014usually less than 1 milliamp. If it\u2019s higher, that means the lightning surge damaged the internal components, and it\u2019s not going to work the next time a storm hits.<\/p>\n<p>Wait, I\u2019ve seen people skip this test and just assume if the lights stayed on, the LA\u2019s fine. That\u2019s a mistake. Lightning can strike nearby, create a surge, and the LA might have absorbed that, but the surge still did damage. Last year, a guy told me his \u201csurge protector for the whole house\u201d (which was actually a LA) worked because his TV didn\u2019t break\u2014turns out the internal MOVs were already halfway gone, and the next big storm would\u2019ve fried his HVAC. So testing non-visible damage is non-negotiable.<\/p>\n<p>Also, let\u2019s talk about age. A lightning arrester that\u2019s 10 years old? It\u2019s gonna wear out, even without a strike. They don\u2019t last forever\u2014heat, humidity, UV from the sun, all that stuff degrades them over time. If a storm rolls through and you notice your LA\u2019s 12 years old, that\u2019s a double whammy. The strike might\u2019ve pushed it past its limit. Even if the tests come back \u201cokay,\u201d I\u2019d lean toward replacing it just to be safe\u2014your equipment\u2019s worth more than a new LA.<\/p>\n<p>What about if it\u2019s a gas-filled arrester? Wait, those are less common now, mostly in older systems. If you have one, check for a pressure relief vent. A lot of gas-filled units have a little button or a disc that pops out if the internal pressure gets too high from a strike. If that vent\u2019s popped, the gas leaked out, and the arrester\u2019s useless. That\u2019s a big one\u2014we had a commercial client who didn\u2019t notice their vent popped after a storm, and a week later another strike fried their entire backup generator. Cost \u2018em way more than replacing the arrester would\u2019ve.<\/p>\n<p>Let me throw in a real story here, \u2018cause that\u2019s what we do. Back in 2021, a farm down in Ohio called us after a storm. They had three LAs on their grain silo transformers. The visual check looked fine\u2014no cracks, no discoloration. So they ran the megger test. One of the three had an insulation resistance of 200 megaohms\u2014way below the normal 10k. We sent our guy out to take a look, and when he opened the unit, the MOVs inside were all crumbly\u2014lightning had fried them from the inside out. That farm avoided losing $50k worth of grain (they were harvesting that week) just \u2018cause they tested. If they\u2019d skipped, next time a strike hit, no LA meant no protection.<\/p>\n<p>Another common mistake: people think if the LA is still \u201cin one piece,\u201d it\u2019s good. Nope. I\u2019ve seen LAs that looked totally intact on the outside, but inside, the varistors were shorted. The surge made the internal metal expand so fast, it cracked the MOVs without breaking the ceramic. So visual checks are step one, not step all.<\/p>\n<p>What should you do if you think your LA is damaged? First, get a pro. Don\u2019t mess with high-voltage stuff if you\u2019re not trained\u2014seriously, that\u2019s how people get hurt. A licensed electrician or a LA technician can do the tests, tell you if it\u2019s repairable (most of the time, they\u2019re not\u2014you replace \u2018em) or if you need a new one.<\/p>\n<p>Now, as a supplier, I\u2019ll be honest with you: we\u2019ve seen our fair share of LAs that looked like they took a direct hit, tested fine, and kept working. But we\u2019ve also seen ones that looked brand new, tested bad, and failed 3 months later. The key here is consistency\u2014don\u2019t just check after a big storm. Do a quick visual once a year, especially if you\u2019re in a lightning-prone area (Florida, Texas, the Plains\u2014we see a lot of clients there). And if you have a storm with really heavy lightning, give your LAs a once-over.<\/p>\n<p>Wait, one more thing: what if the system has a surge protective device (SPD) instead of a LA? They\u2019re different\u2014SPDs are for inside your building, LAs are for outside on the power lines. But the same logic applies: if there\u2019s a storm surge, check the SPD for a blown fuse or a little indicator window that turns red. If that\u2019s the case, replace it too. But this blog\u2019s about LAs, so I\u2019ll stick to that.<\/p>\n<p>Let\u2019s wrap this up. To recap, here\u2019s your quick checklist:<\/p>\n<ol>\n<li>Visual check after storms: Look for cracked ceramic, burnt discoloration, loose connections, popped pressure vents (for gas units).<\/li>\n<li>Electrical test: Megger insulation resistance (aim for 10k+ megaohms), check leakage current (under 1 milliamp).<\/li>\n<li>Factor in age: If it\u2019s over 10 years old, even if it looks fine, think about replacement\u2014wear and tear makes damage more likely.<\/li>\n<\/ol>\n<p>I know this stuff can feel overwhelming, especially if you\u2019re new to the electrical side. That\u2019s why we\u2019re here. Whether you need a replacement LA, a quick answer to a question, or help scheduling a tech to come test your units, don\u2019t hesitate to reach out. We\u2019ve got years of experience, and we\u2019re not just a supplier\u2014we\u2019re folks who work on the same job sites you do, so we get how important this is.<\/p>\n<p>Now, before I go, let\u2019s list the sources I relied on for all this stuff\u2014nothing fancy, just the real industry stuff we use every day.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.blooming-tech.net\/uploads\/47475\/small\/meteorological-detection-uav6de26.png\"><\/p>\n<p>References:<\/p>\n<ul>\n<li>IEEE Standard for Surge Arresters for AC Power Circuits (IEEE C62.11)<\/li>\n<li>National Electrical Code (NEC) Article 280, Surge Arresters<\/li>\n<li>Lightning Protection Institute (LPI) Technical Bulletin on Arrester Damage Assessment<\/li>\n<li>\u201cLightning Surge Effects on Distribution Equipment\u201d by the Electrical Power Research Institute (EPRI)<\/li>\n<li>Our own 12 years of on-site testing and client troubleshooting data.<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.blooming-tech.net\/meteorological-instruments\/meteorological-sounding-system\/\">Meteorological Sounding System<\/a> That\u2019s it, folks. Stay safe out there, and when in doubt, check your LAs. We\u2019re here if you need us for all your lightning protection needs.<\/p>\n<hr>\n<p><a href=\"https:\/\/www.blooming-tech.net\/\">Tianjin Blooming Technology Ltd.<\/a><\/p>\n<p>Address: Main Building, No. 10 Wuhua Road, Huayuan Industrial Zone, Binhai High-tech Zone, Tianjin, China<br \/>E-mail: sales@blooming-tech.com<br \/>WebSite: <a href=\"https:\/\/www.blooming-tech.net\/\">https:\/\/www.blooming-tech.net\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hey there, fellow folks in the electrical game! I\u2019m Jake, part of the team that\u2019s been &hellip; <a title=\"How can I tell if a lightning arrester has been damaged by a lightning strike?\" class=\"hm-read-more\" href=\"http:\/\/www.novdim.com\/blog\/2026\/11\/09\/how-can-i-tell-if-a-lightning-arrester-has-been-damaged-by-a-lightning-strike-495a-c23e85\/\"><span class=\"screen-reader-text\">How can I tell if a lightning arrester has been damaged by a lightning strike?<\/span>Read more<\/a><\/p>\n","protected":false},"author":78,"featured_media":643,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[606],"class_list":["post-643","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-lightning-arrester-455d-c288a0"],"_links":{"self":[{"href":"http:\/\/www.novdim.com\/blog\/wp-json\/wp\/v2\/posts\/643","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.novdim.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.novdim.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.novdim.com\/blog\/wp-json\/wp\/v2\/users\/78"}],"replies":[{"embeddable":true,"href":"http:\/\/www.novdim.com\/blog\/wp-json\/wp\/v2\/comments?post=643"}],"version-history":[{"count":0,"href":"http:\/\/www.novdim.com\/blog\/wp-json\/wp\/v2\/posts\/643\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.novdim.com\/blog\/wp-json\/wp\/v2\/posts\/643"}],"wp:attachment":[{"href":"http:\/\/www.novdim.com\/blog\/wp-json\/wp\/v2\/media?parent=643"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.novdim.com\/blog\/wp-json\/wp\/v2\/categories?post=643"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.novdim.com\/blog\/wp-json\/wp\/v2\/tags?post=643"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}